Customization: | Available |
---|---|
Communication Mode: | Full-Duplex & Half-Duplex |
Type: | Ethernet Switch |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
F5's migration tool, Journeys, helps users adopt newer platforms like rSeries by providing
a frictionless migration experience. It allows users to migrate from any source platform (F5
chassis, appliance, or VE) running BIG-IP software to the platform of their choice. The tool
assists in checking feature compatibility issues between different platforms and software
versions, identifying and troubleshooting migration issues, and reducing overall complexity
and time spent on migration. It's a single tool with an easy-to-use GUI interface that helps to
migrate all the L4-L7 customer configurations with minimal disruption to a customer's existing
operational procedures. This tool also provides post-migration validation metrics in terms of
the memory footprint, cluster status, and configuration object count, for improved visibility into
the migration status and reduced runtime issues.
|
Specifications Intelligent Traffic Processing: |
r10900 L7 requests per second: 6.6M L4 connections per second: 2.5M L4 HTTP requests per second: 37M Maximum L4 concurrent connections: 180M Throughput: 190 Gbps/190 Gbps L4/L7 |
r10800 L7 requests per second: 5.5M L4 connections per second: 2.1M L4 HTTP requests per second: 36M Maximum L4 concurrent connections: 160M Throughput: 190 Gbps/145 Gbps L4/L7 |
||||||||
Hardware Offload SSL/TLS: | 200K TPS (RSA 2k keys) 140K TPS (ECDHE-ECDSA P-256) 110K TPS (ECDHE P-256-RSA 2k) 95 Gbps bulk encryption |
150K TPS (RSA 2k keys) 110K TPS (ECDHE-ECDSA P-256) 110K TPS (ECDHE P-256-RSA 2k) 80 Gbps bulk encryption |
||||||||
Hardware Compression: | 90 Gbps | 80 Gbps | ||||||||
Hardware DDoS Protection: | 160M SYN Cookies per second | 160M SYN Cookies per second | ||||||||
Software Architecture: | 64-bit TMOS 64-bit F5OS |
64-bit TMOS 64-bit F5OS |
||||||||
Multi-Tenancy: | Up to 36 | Up to 28 | ||||||||
Processor: | 12 vCPU's Reserved for F5OS, and 36 vCPU's Available for Tenancy. |
12 vCPU's Reserved for F5OS, and 28 vCPU's Available for Tenancy. |
||||||||
Memory: | 256 GB DDR | 256 GB DDR | ||||||||
Hard Drive: | 2x 1TB U.2 Enterprise-class SSD (RAID 1 Mirrored) | 2x 1TB U.2 Enterprise-class SSD (RAID1 Mirrored) | ||||||||
Management Ports: | 1x 1000BASE-T, 1x USB 3.0, 1x serial console |
1x 1000BASE-T, 1x USB 3.0, 1x serial console |
||||||||
100/40 Gigabit Fiber Ports: | 4 x 100G/40G QSFP28/QSFP+ ports | 4 x 100G/40G QSFP28/QSFP+ ports | ||||||||
25/10 Gigabit Fiber Ports: | 16 x 25G/10G SFP28/SFP+ ports | 16 x 25G/10G SFP28/SFP+ ports | ||||||||
Power Supply: | 2 x 1200 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
2 x 1200 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
||||||||
Typical Consumption: | 680W (dual power supply, 48V DC or 110V AC input) | 680W (dual power supply, 48V DC or 110V AC input) | ||||||||
Input Voltage / Typical Heat generated: |
Dual Power supply 110 VAC input: 2325 BTU/hour 230 VAC input: 2290 BTU/hour |
Dual Power supply 110 VAC input: 2325 BTU/hour 230 VAC input: 2290 BTU/hour |
||||||||
Dimensions: | H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 30.6 inches (77.72 cm) (per unit) 1U industry standard rack-mount chassis |
H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 30.6 inches (77.72 cm) (per unit) 1U industry standard rack-mount chassis |
||||||||
Weight: | 36.0 pounds (16.33 kg) with two power supply units (PSUs) (per unit) |
36.0 pounds (16.33 kg) with two power supply units (PSUs) (per unit) |
||||||||
Operating Temperature: | 32 to 104°F (0 to 40°C) | 32 to 104°F (0 to 40°C) | ||||||||
Operational Relative Humidity: | 5% to 85% (40 C) non-condensing | 5% to 85% (40 C) non-condensing | ||||||||
Hardware Certification Model | r10000 | r10000 | ||||||||
Safety Agency Approval: | ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 (Second Edition) EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, UL 62368-1, 2nd edition |
ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 (Second Edition) EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, UL 62368-1, 2nd edition |
||||||||
Certifications / Susceptibility Standards: |
FCC Class A (Part 15), IC Class A; VCCI Class A EN 55032:2012/AC:2013 Class A EN 55035:2017 EN 300 386 V1.6.1 (2012) |
FCC Class A (Part 15), IC Class A; VCCI Class A EN 55032:2012/AC:2013 Class A EN 55035:2017 EN 300 386 V1.6.1 (2012) |
||||||||
Specifications Intelligent Traffic Processing: |
r10600 L7 requests per second: 4.5M L4 connections per second: 1.9M L4 HTTP requests per second: 36M Maximum L4 concurrent connections: 145M Throughput: 190 Gbps/125 Gbps L4/L7 |
r5900 L7 requests per second: 4.3M L4 connections per second: 1.8M L4 HTTP requests per second: 18M Maximum L4 concurrent connections: 100M Throughput: 95 Gbps/95 Gbps L4/L7 |
||||||||
Hardware Offload SSL/TLS: | 115K TPS (RSA 2k keys) 90K TPS (ECDHE-ECDSA P-256) 90K TPS (ECDHE P-256-RSA-2k) 75 Gbps bulk encryption |
100K TPS (RSA 2k keys) 70K TPS (ECDHE-ECDSA P-256) 55K TPS (ECDHE P-256-RSA-2k) 50 Gbps bulk encryption |
||||||||
Hardware Compression: | 80 Gbps | 50 Gbps | ||||||||
Hardware DDoS Protection: | 160M SYN Cookies per second | 80M SYN Cookies per second | ||||||||
Software Architecture: | 64-bit TMOS 64-bit F5OS |
64-bit TMOS 64-bit F5OS |
||||||||
Multi-Tenancy: | Up to 24 | Up to 26 | ||||||||
Processor: | 12 vCPU's Reserved for F5OS, and 24 vCPU's Available for Tenancy. |
6 vCPU's Reserved for F5OS, and 26 vCPU's Available for Tenancy. |
||||||||
Memory: | 256 GB DDR | 128 GB DDR | ||||||||
Hard Drive: | 2x 1TB U.2 Enterprise-class SSD (RAID1 Mirrored) | 1x 1TB M.2 SSD | ||||||||
Management Ports: | 1x 1000BASE-T, 1x USB 3.0, 1x serial console |
1x 1000BASE-T, 1x USB 3.0, 1x serial console |
||||||||
100/40 Gigabit Fiber Ports: | 4 x 100G/40G QSFP28/QSFP+ ports | 2 x 100G/40G QSFP28/QSFP+ ports | ||||||||
25/10 Gigabit Fiber Ports: | 16 x 25G/10G SFP28/SFP+ ports | 8 x 25G/10G SFP28/SFP+ ports | ||||||||
Power Supply: | 2 x 1200 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
1 x 650 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
||||||||
Typical Consumption: | 680W (dual power supply, 48V DC or 110V AC input) | 425W (single power supply, 48V DC or 110V AC input) | ||||||||
Input Voltage / Typical Heat generated: |
Dual Power supply 110 VAC input: 2325 BTU/hour 230 VAC input: 2290 BTU/hour |
Single Power supply 110 VAC input: 1455 BTU/hour 230 VAC input: 1420 BTU/hour |
||||||||
Dimensions: | H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 30.6 inches (77.72 cm) (per unit) 1U industry standard rack-mount chassis |
H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 30.6 inches (77.72 cm) (per unit) 1U industry standard rack-mount chassis |
||||||||
Weight: | 36.0 pounds (16.33 kg) with two power supply units (PSUs) (per unit) |
36.0 pounds (16.33 kg) with two power supply units (PSUs) (per unit) |
||||||||
Operating Temperature: | 32 to 104°F (0 to 40°C) | 32 to 104°F (0 to 40°C) | ||||||||
Operational Relative Humidity: | 5% to 85% (40 C) non-condensing | 5% to 85% (40 C) non-condensing | ||||||||
Hardware Certification Model | r10000 | r5000 | ||||||||
Safety Agency Approval: | ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 (Second Edition) EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, UL 62368-1, 2nd edition |
ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 (Second Edition) EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, UL 62368-1, 2nd edition |
||||||||
Certifications / Susceptibility Standards: |
FCC Class A (Part 15), IC Class A; VCCI Class A EN 55032:2012/AC:2013 Class A EN 55035:2017 EN 300 386 V1.6.1 (2012) |
FCC Class A (Part 15), IC Class A; VCCI Class A EN 55032:2012/AC:2013 Class A EN 55035:2017 EN 300 386 V1.6.1 (2012) |
||||||||
Specifications Intelligent Traffic Processing: |
r5800 L7 requests per second: 3.3M L4 connections per second: 1.4M L4 HTTP requests per second: 18M Maximum L4 concurrent connections: 85M Throughput: 95 Gbps/85 Gbps L4/L7 |
r5600 L7 requests per second: 2.5M L4 connections per second: 1M L4 HTTP requests per second: 18M Maximum L4 concurrent connections: 75M Throughput: 95 Gbps/60 Gbps L4/L7 |
||||||||
Hardware Offload SSL/TLS: | 80K TPS (2K SSL TPS) 50K TPS (ECDHE-ECDSA P-256 TPS) 50K TPS (ECDHE P-256-RSA-2k TPS) 45 Gbps bulk encryption |
60K TPS (2K SSL TPS) 30K TPS (ECDHE-ECDSA P-256 TPS) 30K TPS (ECDHE P-256-RSA-2k TPS) 35 Gbps bulk encryption |
||||||||
Hardware Compression: | 40 Gbps | 35 Gbps | ||||||||
Hardware DDoS Protection: | 80M SYN Cookies per second | 80M SYN Cookies per second | ||||||||
Software Architecture: | 64-bit TMOS 64-bit F5OS |
64-bit TMOS 64-bit F5OS |
||||||||
Multi-Tenancy: | Up to 18 | Up to 8 | ||||||||
Processor: | 6 vCPU's Reserved for F5OS, and 18 vCPU's Available for Tenancy. |
6 vCPU's Reserved for F5OS, and 12 vCPU's Available for Tenancy. |
||||||||
Memory: | 128 GB DDR | 128 GB DDR | ||||||||
Hard Drive: | 1x 1TB M.2 SSD | 1x 1TB M.2 SSD | ||||||||
Management Ports: | 1x 1000BASE-T, 1x USB 3.0, 1x serial console |
1x 1000BASE-T, 1x USB 3.0, 1x serial console |
||||||||
100/40 Gigabit Fiber Ports: | 2 x 100G/40G QSFP+/QSFP28 ports | 2 x 100G/40G QSFP+/QSFP28 ports | ||||||||
25/10 Gigabit Fiber Ports: | 8 x 25G/10G SFP28/SFP+ ports | 8 x 25G/10G SFP28/SFP+ ports | ||||||||
Power Supply: | 1 x 650 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
1 x 650 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
||||||||
Typical Consumption: | 425W (single power supply, 48V DC or 110V AC input) | 425W (single power supply, 48V DC or 110V AC input) | ||||||||
Input Voltage / Typical Heat generated: |
Single Power supply 110 VAC input: 1455 BTU/hour 230 VAC input: 1420 BTU/hour |
Single Power supply 110 VAC input: 1455 BTU/hour 230 VAC input: 1420 BTU/hour |
||||||||
Dimensions: | H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 30.6 inches (77.72 cm) (per unit) 1U industry standard rack-mount chassis |
H: 1.72 inches (4.37 cm) x W: 17.4 inches (44.20 cm) x D: 30.6 inches (77.72 cm) (per unit) 1U industry standard rack-mount chassis |
||||||||
Weight: | 36.0 pounds (16.33 kg) with two power supply units (PSUs) (per unit) |
36.0 pounds (16.33 kg) with two power supply units (PSUs) (per unit) |
||||||||
Operating Temperature: | 32 to 104°F (0 to 40°C) | 32 to 104°F (0 to 40°C) | ||||||||
Operational Relative Humidity: | 5% to 85% (40 C) non-condensing | 5% to 85% (40 C) non-condensing | ||||||||
Hardware Certification Model | r5000 | r5000 | ||||||||
Safety Agency Approval: | ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 (Second Edition) EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, UL 62368-1, 2nd edition |
ANSI/UL 60950-1-2014 CSA 60950-1-07, including A1:2011+A2:2014 IEC 60950-1:2005, A1:2009+A2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 (Second Edition) EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, UL 62368-1, 2nd edition |
||||||||
Certifications / Susceptibility Standards: |
FCC Class A (Part 15), IC Class A; VCCI Class A EN 55032:2012/AC:2013 Class A EN 55035:2017 EN 300 386 V1.6.1 (2012) |
FCC Class A (Part 15), IC Class A; VCCI Class A EN 55032:2012/AC:2013 Class A EN 55035:2017 EN 300 386 V1.6.1 (2012) |
||||||||
Specifications Intelligent Traffic Processing: |
r4800 L7 requests per second: 1.8M L4 connections per second: 750K L4 HTTP requests per second: 3.5M Maximum L4 concurrent connections: 38M Throughput: 50 Gbps/40 Gbps L4/L7 |
r4600 L7 requests per second: 1.3M L4 connections per second: 500K L4 HTTP requests per second: 2.5M Maximum L4 concurrent connections: 38M Throughput: 40 Gbps/30 Gbps L4/L7 |
||||||||
Hardware Offload SSL/TLS: | 45K TPS (2K SSL TPS) 20K TPS (ECDHE-ECDSA P-256 TPS) 20K TPS (ECDHE P-256-RSA 2k TPS) 25 Gbps bulk encryption |
30K TPS (2K SSL TPS) 14K TPS (ECDHE-ECDSA P-256 TPS) 14K TPS (ECDHE P-256-RSA 2k TPS) 20 Gbps bulk encryption |
||||||||
Compression: | 30 Gbps (Hardware) | 20 Gbps (Software) | ||||||||
Software Architecture: | 64-bit TMOS 64-bit F5OS |
64-bit TMOS 64-bit F5OS |
||||||||
Multi-Tenancy: | Up to 4 | Up to 2 | ||||||||
Processor: | 1 x 16-Core Intel® Atom® processor (16 CPUs available for Tenancy) |
1 x 16-Core Intel® Atom® processor (12 CPUs available for Tenancy) |
||||||||
Memory: | 64 GB DDR | 64 GB DDR | ||||||||
Hard Drive: | 480GB M.2 SSD | 480GB M.2 SSD | ||||||||
Management Ports: | 1x 1000BASE-T, 1x USB 3.0, 1x serial console |
1x 1000BASE-T, 1x USB 3.0, 1x serial console |
||||||||
10G/1G Gigabit Copper Ports: | 4 x 10G/1G RJ45 Ports | 4 x 10G/1G RJ45 Ports | ||||||||
25/10/1G Gigabit Fiber Ports: | 4 x 25G/10G/1G SFP+/SFP28/SFP ports | 4 x 25G/10G/1G SFP+/SFP28/SFP ports | ||||||||
Power Supply: | 1 x 250 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
1 x 250 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
||||||||
Typical Consumption: | 105W (single power supply, 48V DC or 110V AC input) | 105W (single power supply, 48V DC or 110V AC input) | ||||||||
Input Voltage / Typical Heat generated: |
Single Power supply 110 VAC input: 360 BTU/hour 230 VAC input: 345 BTU/hour |
Single Power supply 110 VAC input: 360 BTU/hour 230 VAC input: 345 BTU/hour |
||||||||
Dimensions: | H: 1.74 inches (4.37 cm) x W: 19 inches (Standard rack) x D: 16.9 inches (42.9 cm). 1U industry standard rack-mount chassis |
H: 1.74 inches (4.37 cm) x W: 19 inches (Standard rack) x D: 16.9 inches (42.9 cm). 1U industry standard rack-mount chassis |
||||||||
Weight: | 20.0 pounds (9.07 kg) with one power supply units (PSUs) (per unit) |
20.0 pounds (9.07 kg) with one power supply units (PSUs) (per unit) |
||||||||
Operating Temperature: | 32 to 104°F (0 to 40°C) | 32 to 104°F (0 to 40°C) | ||||||||
Operational Relative Humidity: | 5% to 85% (40 C) non-condensing | 5% to 85% (40 C) non-condensing | ||||||||
Hardware Certification Model | r4000 | r4000 | ||||||||
Safety Agency Approval: | ANSI/UL 60950-1-2014 CSA 60950-1-07, A1:2011+A2:2014 IEC 60950-1:2005, IEC 60950-1:2005/AMD1:2009, IEC 60950- 1:2005/AMD2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, ANSI/UL 62368-1, 2nd edition |
ANSI/UL 60950-1-2014 CSA 60950-1-07, A1:2011+A2:2014 IEC 60950-1:2005, IEC 60950-1:2005/AMD1:2009, IEC 60950- 1:2005/AMD2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, ANSI/UL 62368-1, 2nd edition |
||||||||
Certifications / Susceptibility Standards: |
47 CFR FCC Part 15, Subpart B, Class A EN 55032:2015 +A11:2020, Class A EN 55035:2017 +A11:2020 EN 300 386 V2.1.1 (2016-07) |
47 CFR FCC Part 15, Subpart B, Class A EN 55032:2015 +A11:2020, Class A EN 55035:2017 +A11:2020 EN 300 386 V2.1.1 (2016-07) |
||||||||
Specifications Intelligent Traffic Processing: |
r4800 L7 requests per second: 1.8M L4 connections per second: 750K L4 HTTP requests per second: 3.5M Maximum L4 concurrent connections: 38M Throughput: 50 Gbps/40 Gbps L4/L7 |
r4600 L7 requests per second: 1.3M L4 connections per second: 500K L4 HTTP requests per second: 2.5M Maximum L4 concurrent connections: 38M Throughput: 40 Gbps/30 Gbps L4/L7 |
||||||||
Hardware Offload SSL/TLS: | 45K TPS (2K SSL TPS) 20K TPS (ECDHE-ECDSA P-256 TPS) 20K TPS (ECDHE P-256-RSA 2k TPS) 25 Gbps bulk encryption |
30K TPS (2K SSL TPS) 14K TPS (ECDHE-ECDSA P-256 TPS) 14K TPS (ECDHE P-256-RSA 2k TPS) 20 Gbps bulk encryption |
||||||||
Compression: | 30 Gbps (Hardware) | 20 Gbps (Software) | ||||||||
Software Architecture: | 64-bit TMOS 64-bit F5OS |
64-bit TMOS 64-bit F5OS |
||||||||
Multi-Tenancy: | Up to 4 | Up to 2 | ||||||||
Processor: | 1 x 16-Core Intel® Atom® processor (16 CPUs available for Tenancy) |
1 x 16-Core Intel® Atom® processor (12 CPUs available for Tenancy) |
||||||||
Memory: | 64 GB DDR | 64 GB DDR | ||||||||
Hard Drive: | 480GB M.2 SSD | 480GB M.2 SSD | ||||||||
Management Ports: | 1x 1000BASE-T, 1x USB 3.0, 1x serial console |
1x 1000BASE-T, 1x USB 3.0, 1x serial console |
||||||||
10G/1G Gigabit Copper Ports: | 4 x 10G/1G RJ45 Ports | 4 x 10G/1G RJ45 Ports | ||||||||
25/10/1G Gigabit Fiber Ports: | 4 x 25G/10G/1G SFP+/SFP28/SFP ports | 4 x 25G/10G/1G SFP+/SFP28/SFP ports | ||||||||
Power Supply: | 1 x 250 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
1 x 250 W 100-240 VAC (+/- 10%) AUTO Switching Platinum, Dual DC PSU Optional |
||||||||
Typical Consumption: | 105W (single power supply, 48V DC or 110V AC input) | 105W (single power supply, 48V DC or 110V AC input) | ||||||||
Input Voltage / Typical Heat generated: |
Single Power supply 110 VAC input: 360 BTU/hour 230 VAC input: 345 BTU/hour |
Single Power supply 110 VAC input: 360 BTU/hour 230 VAC input: 345 BTU/hour |
||||||||
Dimensions: | H: 1.74 inches (4.37 cm) x W: 19 inches (Standard rack) x D: 16.9 inches (42.9 cm). 1U industry standard rack-mount chassis |
H: 1.74 inches (4.37 cm) x W: 19 inches (Standard rack) x D: 16.9 inches (42.9 cm). 1U industry standard rack-mount chassis |
||||||||
Weight: | 20.0 pounds (9.07 kg) with one power supply units (PSUs) (per unit) |
20.0 pounds (9.07 kg) with one power supply units (PSUs) (per unit) |
||||||||
Operating Temperature: | 32 to 104°F (0 to 40°C) | 32 to 104°F (0 to 40°C) | ||||||||
Operational Relative Humidity: | 5% to 85% (40 C) non-condensing | 5% to 85% (40 C) non-condensing | ||||||||
Hardware Certification Model | r4000 | r4000 | ||||||||
Safety Agency Approval: | ANSI/UL 60950-1-2014 CSA 60950-1-07, A1:2011+A2:2014 IEC 60950-1:2005, IEC 60950-1:2005/AMD1:2009, IEC 60950- 1:2005/AMD2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, ANSI/UL 62368-1, 2nd edition |
ANSI/UL 60950-1-2014 CSA 60950-1-07, A1:2011+A2:2014 IEC 60950-1:2005, IEC 60950-1:2005/AMD1:2009, IEC 60950- 1:2005/AMD2:2013 EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 IEC 62368-1:2014 EN 62368-1:2014+A11:2017 CSA C22.2 No. 62368-1-14, ANSI/UL 62368-1, 2nd edition |
||||||||
Certifications / Susceptibility Standards: |
47 CFR FCC Part 15, Subpart B, Class A EN 55032:2015 +A11:2020, Class A EN 55035:2017 +A11:2020 EN 300 386 V2.1.1 (2016-07) |
47 CFR FCC Part 15, Subpart B, Class A EN 55032:2015 +A11:2020, Class A EN 55035:2017 +A11:2020 EN 300 386 V2.1.1 (2016-07) |
||||||||
F5 Load Balancer is sealed in original box. We will also pack F5 Load Balancer with second box before shipping.
F5 Load Balancer Payment Method
T/T,Western Union and Money Gram will be accept. Faster payment will help you to get the items earlier.
F5 Load Balancer Shipment Method
The F5 Load Balancer will be send via FedEx,DHL,TNT,UPS,EMS and so on. but the buyer is responsible for customs clearance and pay tariff when F5 Load Balancer arrived destination country.
Q. Are your products in factory sealed packaging?